VSI COBOL V3.5-2 for OpenVMS x86-64 Systems
Release Notes
- Operating System:
- VSI OpenVMS x86-64 Version 9.2-2 or higher
- Software Version:
- VSI COBOL
V3.5-2
for OpenVMS x86-64
1. Introduction
VSI COBOL V3.5-2 for OpenVMS x86-64 Systems provides a COBOL compiler for systems running OpenVMS x86-64 version 9.2-2 or higher.
Note
VSI strongly recommends using OpenVMS x86-64 V9.2-3 + Update 3 or higher, as it includes run-time library fixes, system condition handling improvements, and debugger enhancements.
This document provides general information about VSI COBOL and describes corrections, known issues, and documentation resources relevant to this release.
The image identification for the COBOL compiler is "COBOL V3.5-2".
The COBOL/VERSION string is:
VSI COBOL V3.5-2 (GEM 50nnn) on OpenVMS x86-64 Systems1.1. Getting Help and Reporting Problems
Please report problems or provide feedback through the VSI Support Portal or VSI Official Forum.
2. Release Notes
VSI COBOL V3.5-2 for OpenVMS x86-64 Systems is based on VSI COBOL for OpenVMS IA-64 and is intended to provide a high degree of source compatibility. Some platform-specific features available on OpenVMS Alpha or OpenVMS IA-64 systems may not be supported on OpenVMS x86-64.
2.1. /CONVERT=LEADING_BLANKS Compatibility Behavior
The HELP text for previous COBOL compilers on OpenVMS IA-64 and OpenVMS x86-64
states that the /CONVERT=LEADING_BLANKS qualifier is disabled by
default. While this is true for OpenVMS Alpha, OpenVMS IA-64 enables this behavior
by default in the run-time library, and it cannot be disabled through the
/CONVERT qualifier.
On OpenVMS x86-64 systems, VSI COBOL V3.4 and earlier did not perform this
automatic conversion, matching the behavior of OpenVMS Alpha. To assist customers
porting from OpenVMS IA-64, VSI COBOL V3.5 and later enable
/CONVERT=LEADING_BLANKS behavior by default, with no option
to disable it.
2.2. Corrections in VSI COBOL V3.5-2
VSI COBOL V3.5-2 includes the following corrections and improvements:
Improved debug information generation for the main entry point to prevent duplicate symbols from being presented to the OpenVMS Debugger.
When
/LIST=MACHINE_CODEis specified, the compiler now callsANALYZE/OBJECT/DISASSEMBLEautomatically.Improved compilation performance for programs containing data structures with a large number of possible re-initialization values. For example:
01 X_REF_ARRAY. 05 FETCH_ARRAY. 15 FETCH_LINE PIC X(40) VALUE "ZZZZZZZZZZZZZ" 05 SEARCH_X_REF_TABLE REDEFINES FETCH_ARRAY OCCURS 500000 TIMES ASCENDING KEY IS XR_GROUP, XR_PR_VALUE, XR_SEC_VALUE INDEXED BY DIR-INDX. 15 XR_GROUP PIC X(8). 15 XR_PR_VALUE PIC X(16). 15 XR_SEC_VALUE PIC X(16).Improved debug information generation for COBOL
REDEFINESdata items.
2.3. Corrections in Previous Releases
The following corrections were introduced in earlier VSI COBOL releases:
Corrected debug information that could cause the debugger to stop on an incorrect source line when using "GO to reach start of program."
[NS7964] Corrected an issue that could cause a COBOL application using the
USE AFTER STANDARD ERROR PROCEDUREclause to terminate with an ACCVIO. This correction requires both the compiler update and the RTL updates provided with OpenVMS x86-64 V9.2-3.[NS8056] Corrected a stack memory leak that could cause certain COBOL applications to terminate with an ACCVIO.
Corrected an issue in which debug information was not generated correctly for programs containing multiple entry points.
Corrected an issue in which incorrect debug information could be generated for decimal field sizes.
Corrected an issue in which the compiler did not produce correct checking code for invalid decimal values even when
/CHECK=DECIMALwas used.
2.4. Known Issues
The following known issues apply to VSI COBOL V3.5-2:
While debugger support has been improved with VSI COBOL V3.5-2 when used with OpenVMS x86-64 V9.2-3 + Update 3 or higher, some limitations remain. Additional improvements are planned for a future release.
The compiler now generates DWARF information for packed-decimal variables, but full debugger support will be implemented in the future. The following is an example of current output for COBOL's PIC 99 with value 12:
DBG> SHOW SYMBOL/TYPE VAR_DECIMAL data TEST_DEBUG\TEST_DEBUG\VAR-DECIMAL atomic type, undefined type, size: 2 bytes DBG> DBG> EXAMINE VAR_DECIMAL TEST_DEBUG\TEST_DEBUG\VAR-DECIMAL: 12849 DBG>
3. VSI COBOL Documentation
The VSI COBOL documentation set can be found online at https://docs.vmssoftware.com/.
At the time of publication, the VSI COBOL documentation has not yet been updated to include information specific to OpenVMS x86-64 support.